Compare Roof Deicing Cables
|
|
SELF REGULATING CABLES
|
MINERAL INSULATED CABLES
|
|
|
CO
Series
|
IN
Series
|
Copper
Sheath
|
Copper Sheath With H.D.P.E. Overjacket
|
Alloy 825
S.S. Sheath
|
|
Wattage Output
|
Variable Along Heated Length
|
Variable Along Heated Length
|
Constant Along Heated Length
|
Constant Along Heated Length
|
Constant Along Heated Length
|
|
Custom Built To Order
|
No
|
No
|
Yes
|
Yes
|
Yes
|
|
Factory Or Field Terminated
|
Field
|
Field
|
Factory
|
Factory
|
Factory
|
|
Operating Voltages
|
120 -277
|
120 -277
|
12 - 480
|
12 - 480
|
12 - 480
|
|
Max. Watt Output On A Metal Roof
|
6-10
|
8-14
|
8-12
|
8-12
|
8-12
|
|
Max. Watt Output On A NON-Metal Roof
|
6-8
|
8
|
5-7
|
5-7
|
5-7
|
|
Max. Circuit Length Ft. (m)
|
Up To 380’ (116)
|
Up To 335’ (102)
|
Up To 400’ (122)
|
Up To 400’ (122)
|
Up To 400’ (122)
|
|
30 mA G.F.P.E. Required By National Electric Code
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Roof Materials Approved For
|
Any
|
Any
|
Metal/Ashpalt
|
Metal/Asphalt
|
Metal/Asphalt
|
|
Power Connection Kit
|
PCK-RGP
|
PCK-RG
|
N/A
|
N/A
|
N/A
|
|
Typical Life Expectancy
|
8-10 Years
|
8-10 Years
|
20+ Years
|
20+ Years
|
20+ Years
|
|
Can Use With Ice Melt Panel
|
Yes
|
Yes
|
No
|
No
|
No
|
|
Warranty
|
1 Year
|
5 Years
|
10 Years
|
10 Years
|
10 Years
|
|
Approvals
|
CSA
|
CSA
|
UL, CSA
|
UL, CSA
|
UL, CSA
|
Supporting Content
Compare Products
Case Studies