Compare Snow Melt Cables & Mats
|
M.I. Cable Assembly
|
Snow Melt Mats
|
Step Snow Melt Mats
|
| Stock Sizes Available |
No
|
Yes
|
No
|
Custom Built Sizes
Available |
Yes
|
Yes
|
Yes
|
| Number Of Conductors |
1 or 2
|
1
|
1
|
Field Or
Factory Terminated |
Factory
|
Factory
|
Factory
|
Can Be Used For Tire
Track Snow Melting |
Yes
|
Yes
|
No
|
| Operating Voltages |
120 - 480
|
120 - 480
|
120 - 480
|
Cable Spacing In.
(cm) (15 - 23) |
6” - 9”
|
Not Applicable
|
Not Applicable
|
Max. Watts Per Sq.
Ft. (Sq. m) |
45 - 60
(148 - 197)
|
50 (164)
|
50 (164)
|
Maximum Depth Of
Snow Melting Cable
Or Mat In. (cm) |
Within 3” (8) Of The Surface
|
Within 3” (8) Of The Surface
|
Within 3” (8) Of The Surface
|
Available Widths In.
(cm) (46 - 91) |
Not Applicable
|
18” And 36”
|
|
30 mA G.F.P.E.
Required By National
Electric Code |
No
|
Yes
|
Yes
|
Minimum Coverage Area For Single Cable Or Mat |
| Stock Sq. Ft. (Sq. m) |
Not Applicable
|
7.5 (.7)
|
7.5 (.7)
|
| Custom Sq. Ft. (Sq. m) |
25 (2)
|
6 (.6)
|
6 (.6)
|
Maximum Coverage Area For Single Cable Or Mat |
| Stock Sq. Ft. (Sq. m) |
Not Applicable
|
60 (6)
|
60 (6)
|
| Custom Sq. Ft. (Sq. m) |
300 (28)
|
150 (14)
|
150 (14)
|
Acceptable Embedding Material |
| Concrete |
Yes
|
Yes
|
Yes
|
| Asphalt |
Yes
|
Yes
|
Yes
|
Embedded In Sand
Bed Beneath Pavers |
Yes
|
No
|
No
|
Embedded In
Concrete Beneath
Pavers |
Yes
|
Yes
|
Yes
|
Attachment Method Used To Hold Cable In Place During Embedding |
| Tie To Rebar: |
Yes
|
No
|
No
|
T-SSS Stainless
Steel Strapping: |
Yes
|
No
|
No
|
| Approvals: |
UL, CSA
|
CSA
|
CSA
|
| Warranty: |
10 Years
|
5 Years
|
5 Years
|
Snow Melt Product Info
Compare Products
Case Studies